Skip to content
Free delivery from €4,000 excl. VAT24-hour delivery in the Paris region on in-stock items

Configurators

Air receiver size for your tools

Choose your tools and your compressor: we calculate the receiver volume that absorbs your consumption peaks and limits starts, then the receivers from our catalogue to add.

Result

Air receiver size for your tools

Choose your tools and your compressor: we calculate the receiver volume that absorbs your consumption peaks and limits starts, then the receivers from our catalogue to add.

How this is calculated

The volume shown is the larger of two calculations.

  • Limiting starts: the usual air receiver formula, V = 0.25 × Q × p₀ / (f × Δp), where Q is the compressor flow, p₀ the atmospheric pressure (1.013 bar), f the maximum number of cycles per hour (60 for a screw compressor, 20 for a piston compressor) and Δp the difference between cut-out and cut-in pressure.
  • Absorbing peaks: when the tools used at the same time consume more than the compressor produces, the receiver supplies the difference during the peak: V = (peak Q − compressor Q) × duration × p₀ / Δp.

Peak consumption adds up the most air-hungry tools, as many as there are people working at the same time. Average consumption counts continuous-use tools (sanders, spray guns) in full and intermittent tools at half, with a margin for leaks. The working pressure is that of the most demanding tool, plus 1 bar for network losses.

The volume of the built-in receiver (K series, E series, M series) is deducted. The rest is rounded up to 1,000 L vertical receivers, the capacity of our receivers.

Does a bigger receiver use more energy?

No. A bigger receiver does not use more electricity: it spaces out compressor starts, stabilises the pressure at the tools and lets condensate settle before the network. However, it does not make up for an undersized compressor: if your tools use more air on average than the compressor produces, the pressure will always end up dropping.

Painted or galvanised?

The painted receiver is the most economical choice when a dryer is installed before the receiver: the air entering it is already dry. The hot-dip galvanised receiver, inside and out, resists corrosion even with humid air: it is the right choice without an upstream dryer, in a humid workshop or under an outdoor shelter. Both come in 10 and 13 bar: choose a working pressure at least equal to that of your compressor.