Compressor tripping or stopping on a fault: what to check

A breaker that trips or an alarm that stops the machine is a protection doing its job. How to find out what it is telling you.

When a compressor trips the breaker or stops on an alarm, a protection has reacted. Restarting without looking for the cause only postpones the breakdown, sometimes making it worse. Here is how to find your way.

Safety: diagnosis inside an electrical cabinet is done by a qualified person. Machine locked out, receiver vented.

The workshop breaker trips at start-up

  • Unsuitable protection: starting a motor draws more current than normal running. A breaker that is too small or has the wrong curve trips at every start. The protection is chosen according to the machine's manual.
  • Cable too long or too thin: the voltage drops at start-up and the motor strains.
  • A missing phase on a three-phase machine: the motor cannot start properly.
  • An insulation fault (damaged motor or cable, damp): the residual current device then trips. Do not keep resetting it: have it checked.

With a variable speed compressor, starting is gradual: the inverter limits the inrush current. If it still trips, the problem usually lies in the installation or a fault that needs diagnosing.

The compressor stops and shows an alarm

The controller stops the machine to protect it. Write down the exact message, then:

  • temperature alarm: room ventilation, dirty cooler, oil level (see compressor overheating);
  • motor overload: the machine is straining. Pressure set higher than intended, clogged air/oil separator, voltage too low;
  • inverter fault: often linked to the power supply or the cabinet temperature. Diagnosis is for service;
  • rotation direction or phase fault: after work on the electrical installation, this is the first thing to have checked.

The compressor starts too often

A motor that starts and stops constantly heats up and eventually trips its protections. The usual causes: leaks in the network, a receiver that is too small, too small a gap between stop and restart pressure. See compressor runs constantly or restarts too often and air receiver sizing.

The right reflexes

  1. Note the alarm message and the time.
  2. Check what can be seen without dismantling anything: ventilation, cooler, oil level, pressure gauge.
  3. Reset once. If the fault comes back, leave the machine stopped.
  4. Make a service request from the warranty and service page with the model, serial number, hour meter, message and photos of the screen.

Other symptoms are covered in our compressor troubleshooting guide.